Assess a whole floor in one pass, each room with its own opening type and floor area.
Ventilation
Openable area required for purge ventilation in each habitable room, under Approved Document F.
The proportions have not changed across the editions: 1/20 of the room floor area for an opening of 30° or more, a sliding sash or an external door, and 1/10 between 15° and 30°. The 2021 edition added that below 15° is not suitable at all. Meeting Part F does not on its own satisfy Part O, which usually needs more.
Everything is calculated on this device. When you download a report or save a file, any supplied contact and project details are sent securely to Briary and retained separately from anonymous Tool Insights; calculation values are not retained. Read our tool privacy information.
Assess a whole floor in one pass, each room with its own opening type and floor area.
Enter a room height and the tool gives the extract flow that delivers four air changes an hour instead.
Enter the openable area the window schedule provides and see which rooms fall short, and by how much.
Four air changes an hour is the purge requirement, but the same arithmetic answers any rate for any room: ach = flow × 3.6 ÷ volume.
| Rate | l/s | ach here | This flow |
|---|
Part F sets its extract rates as flows, not as air change rates: 15 l/s in a bathroom is 15 l/s whatever the room's size. Only purge is specified as a rate.
Product data, commissioning sheets and Approved Document F rarely agree on a unit. Every conversion here is exact.
| Unit | Value |
|---|
| Intermittent extract | Required l/s | This flow |
|---|
| Room | Floor area m² | Proportion | Required m² | Provided m² | Result |
|---|
The name and company are printed on the PDF report and are needed before it can be produced. Everything else here is optional and is printed only if you supply it.
Start here, then keep the guide open alongside your work. Expand a section for the information you need.
Have the room dimensions and the opening type and geometry for each room you are checking. Purge ventilation is about clearing pollutants and water vapour quickly, and it is assessed room by room rather than for the dwelling as a whole.
The 2010 and 2021 editions state the purge requirement differently. Establish which applies to the work before entering anything; the tool follows the edition you choose rather than averaging the two.
Floor area and, where the method needs it, the room height. The opening area required follows from the room, so a large room with a small window is the case this calculation exists to catch.
The opening type and its geometry, because a hinged window opening 30 degrees does not deliver what the same window opening fully does. Enter the actual openable geometry rather than the frame size.
The tool gives the openable area required and compares it with what the opening provides. A shortfall is a design problem, not a rounding problem: more openable area, a different opening type, or mechanical purge are the routes out of it.
Background ventilation, extract rates and whole-dwelling rates are separate calculations. So are security, safety, restrictors and anything that limits how far an opening can actually be opened in use — all of which can make a geometrically compliant opening unusable.
The PDF needs your name and company. It records the edition and the room-by-room working. Save inputs writes a .briaryvent file. For problems, email toolsuite@briary.co.uk.
Purge is the one Part F requirement written as an air change rate, so the arithmetic behind it is in the tool: ach = flow × 3.6 ÷ volume. Work either way round — the rate a known fan achieves in a room, or the flow that delivers a rate you are aiming at. Enter the dimensions or a volume you already have, using internal dimensions and, for a sloping ceiling, the average height over the floor area.
The table converts the Approved Document F rates into air changes per hour for the volume you entered, so a flow can be judged against them directly. Read it carefully: Part F states its extract rates as flows, not as rates. Fifteen litres a second in a bathroom is fifteen litres a second whatever the room holds, so a large bathroom shows a low air change rate for the same compliant fan. The fan still complies. Only purge is specified as a rate, at four an hour.
Approved Document F states its rates in litres per second; product data, commissioning sheets and imported equipment rarely do. The Airflow units panel converts between all of them and puts the intermittent extract rates alongside, which is usually the reason for converting. Every conversion is exact rather than approximate: one litre per second is 3.6 cubic metres an hour by definition, and one cubic foot is 0.028316846592 cubic metres exactly, so one cubic foot per minute is 0.4719474 litres per second.
Send the location, project stage and current drawings. We will confirm the assessment route and information needed.