When you need this work

Energy Use Intensity describes the energy a building is expected to use in operation, regulated and unregulated together, divided by its gross internal area. It is a different measure from the regulated-energy output of a compliance calculation.

A Part L or Section 6 calculation answers a Building Regulations question using standardised assumptions. It is not a prediction of metered energy. Where a planning policy, client brief or certification scheme asks for Energy Use Intensity, the assessment has to model the loads a compliance calculation leaves out, including small power, catering, lifts, servers and external lighting, and state the occupancy and operating assumptions behind them.

We agree which target applies and which methodology the recipient expects, then build the prediction on inputs the design team can inspect. Where the requirement also covers space heating demand or later in-use reporting, we set out what has to be measured and by whom.

For the planning narrative that carries this evidence, see energy and sustainability statements.

A glazed commercial frontage with deep reveals providing shading.

What we check

Confirm the target and the method

Policy targets, LETI and RIBA benchmarks, NABERS UK ratings and client briefs do not all define Energy Use Intensity the same way. We confirm the boundary, the floor area basis and the reporting units before any modelling starts, so the figure answers the question actually being asked.

Model the loads compliance ignores

Unregulated energy is often a large share of the total. Small power, catering, lifts, vertical transport, servers, external and car-park lighting and specialist process loads are estimated from the proposed use rather than assumed away.

Show the uncertainty

CIBSE TM54 expects a range rather than a single number, built from stated assumptions about occupancy hours, equipment density and control. We report the range and identify the inputs that move the result most.

Common coordination issue

An Energy Use Intensity figure taken from a SAP or SBEM output is not comparable with a policy target. Compliance tools use standardised occupancy and exclude unregulated loads, so the two numbers describe different things and should not be presented interchangeably.

What you receive

Energy Use Intensity prediction

Predicted annual energy use in kWh/m² GIA, broken down by end use, with the modelled range and the assumptions behind it.

Comparison against the target

The result set against the applicable policy target or benchmark, identifying where the design meets it and where it does not.

Assumptions and actions record

The inputs still to be confirmed and the design decisions with the largest effect on the result, so the team can respond while it can.

Getting started

What we need

Construction materials and insulation samples laid out for review.

Areas and use

Gross internal area by use, floor plans, proposed occupancy, operating hours and any special or process areas.

Services proposals

Heating, cooling, ventilation, hot water, lighting and controls strategy, with efficiencies and any on-site generation or storage where these have been selected.

The requirement itself

The policy, brief or scheme wording that sets the target, the submission stage and the reporting format the recipient expects.

Request an EUI scope

Before commissioning

Is Energy Use Intensity the same as the figure on an EPC?

No. An EPC reports regulated energy under standardised assumptions for a compliance calculation. Energy Use Intensity covers regulated and unregulated energy and is intended to reflect expected operation, so the two should not be compared directly.

Which methodology do you use?

For design-stage operational energy predictions we follow CIBSE TM54, which covers all energy uses and reports a range rather than a single value. Where a policy or scheme names a different method, we use the one the recipient requires and say so in the report.

Do we have to report Energy Use Intensity?

It depends on the authority, the development and its scale. The London Plan energy assessment guidance asks referable applications to report Energy Use Intensity and space heating demand, and some schemes and client briefs set targets outside London. We confirm the applicable requirement for the site before scoping the work.

Does the prediction have to be verified in use?

Only where the requirement says so. Some policies include post-occupancy monitoring and reporting for a defined period after completion. We identify whether that applies and what the ongoing obligation involves.

Sources and further reading

Policy targets, reporting thresholds and methodologies differ between authorities and schemes, and are revised. We confirm the requirement that applies to the site and submission date rather than working from a general benchmark.

Confirm the Energy Use Intensity requirement

Send the site, the policy or brief wording and the current areas and services proposals. We will confirm the applicable target, the method and the information needed.