Building fabric

U-value and condensation-risk calculations

Check walls, roofs and floors using the complete build-up, with material inputs and method limitations recorded.

A close-up of a window installation and surrounding wall junction.

When you need this work

Thermal performance depends on the whole build-up, including repeating bridges, fixings, cavities, tapered layers and the continuity of insulation at interfaces.

We calculate U-values using the applicable conventions for the proposed construction and record the material properties used. Where commissioned and appropriate, we also assess condensation risk using the relevant steady-state method, while explaining its limitations. Complex moisture behaviour may require hygrothermal analysis outside a standard condensation check.

Natural insulation and construction materials beside a timber-framed window.

What we check

Transparent assumptions

Product values, default values and project assumptions are identified separately. This makes the result easier to update and avoids false precision.

Build-up review

We check layer order, thicknesses, framing or repeating members, fixings and cavities. Ambiguous specifications are raised before calculation.

Moisture context

A standard interstitial-condensation calculation is one tool, not a universal guarantee. Exposure, workmanship, initial moisture and dynamic behaviour may need further design consideration.

Common coordination issue

The insulation layer alone does not describe the element. Framing, fixings, cavities and changes in thickness can affect the result. Keep the calculated build-up and the specification issued to procurement aligned.

What you receive

U-value calculation

A documented result with inputs, conventions and assumptions.

Condensation assessment

Surface or interstitial review where included and suitable for the construction.

Design comments

Clarifications or improvement opportunities identified during the build-up review.

Getting started

What we need

A close-up of a modern residential window set in a brick wall.

Construction build-up

Layer sequence, material thicknesses, framing dimensions and spacing, fixings and cavity information.

Performance evidence

Declared thermal conductivities and relevant product or system documentation.

Assessment context

Element type, boundary conditions, project use and any condensation-risk requirement.

Request a fabric calculation

Before commissioning

Can you calculate from a specification note?

Sometimes, but a section or detail is often needed to understand framing, cavities, fixings and layer continuity.

Do standard calculations cover every moisture risk?

No. They have defined assumptions and limitations. More complex or moisture-sensitive assemblies may need specialist hygrothermal analysis.

Can you use a generic material value?

Where the applicable method allows it, but product-specific evidence is preferable when the design relies on that performance.

Sources and further reading

Use the edition, jurisdiction and assessment route that apply to the project. Publication of newer guidance does not automatically change an existing project’s requirements.

Check the detail behind the target U-value

Send the proposed construction, element dimensions and available product data. We will identify any missing information before calculation.

Request a fabric calculation